Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 320

Strict Standards: mktime(): You should be using the time() function instead in /home/dat3f27a/public_html/plugins/system/vvisit_counter/vvisit_counter.php on line 32

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/vvisit_counter/helper/vvisit_counter.php on line 28

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/vvisit_counter/helper/vvisit_counter.php on line 120

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/vvisit_counter/helper/vvisit_counter.php on line 123

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/vvisit_counter/vvisit_counter.php on line 46

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/vvisit_counter/vvisit_counter.php on line 106

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 27

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 44

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 46

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 120

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 125

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/system/k2/k2.php on line 132
LAGD 125- Bơm mỡ tự động
Strict Standards: Non-static method LeoCompressHelper::storeCache() should not be called statically in /home/dat3f27a/public_html/plugins/system/leofw/libs/compress/compress.php on line 63

SKF-Logo-2

Norma Logo jpg

3m logo

Online Support

Sales Dept
Telephone number of Sales Dept 0933.885.662


dai-ly-skf-viet-nam


Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/content/jw_allvideos/jw_allvideos.php on line 42

Strict Standards: Only variables should be assigned by reference in /home/dat3f27a/public_html/plugins/content/jw_allvideos/jw_allvideos.php on line 43

Đại lý nhà phân phối SKF 3M vũng tàu hàng đầu tại Việt Nam

LAGD 125- Bơm mỡ tự động

LAGD-125-SYSTEM24SKF System 24 Singlepoint automatic lubricators LAGD 125 and LAGD 60

BƠM MỠ TỰ ĐỘNG TỪNG ĐIỂM- SKF SYSTEM 24

Gắn cố định vào các gối đỡ hoặc các vị trí khó bôi trơn thường xuyên, ko cần phải định kỳ bôi trơn. Có thể điều chỉnh lượng mỡ tự động bơm vào từng cụm gối đỡ theo đặc tính từng thiết bị, kèm theo phần mềm tính toán lượng mỡ cần bôi trơn cho thiết bị cụ thể. Có tiêu chuẩn chống cháy nổ Ex để sử dụng trong môi trường có khí gas, dầu...

More reliable and easier to use SYSTEM 24 Poor lubrication can considerably reduce the service life of the best of bearings. With that in mind, SKF has enhanced the performance of the single-point automatic lubricator: SYSTEM 24. The lubricator’s increased reliability and ease-of-use are a result of the following:

Product Enhancements

  • Increased reliability at high temperatures as a result of:
    • Transparent lubricant container made of polyamide reduces gas diffusion
    • The larger molecules of the driving inert gas are less sensitive to higher temperatures
  • Intrinsically safe approval for Zone 0:
    • Tested and approved for use in areas where an explosive atmosphere caused by gases, vapours and dust, is continuously present as well as for use in mines and underground areas
  • Easy-to-remove end-cap:
    • Covers the lubricant outlet; sharp tools are no longer required to open the outlet
  • Easy installation:
    • The tool-free activation and time setting slot allows easy and accurate adjustment of lubrication flow
  • Easy and quick fitting:
    • Facilitated by easy-grip top cover

While enhancing the reliability and ease-of-use,SYSTEM 24 still offers you the features and benefits you have to come to expect from SKF automatic lubricators.

  • Flexible time setting period ranging between 1 and 12 months
  • High reliability and dispense rate accuracy allow fit and forget procedure until predetermined replacement date
  • Transparent lubricant container allows visual inspection of dispense rate
  • High capacity, compact size permits installation in restricted areas
  • Redesigned non-return valve of the oil-filled SYSTEM 24 is less sensitive to vibration, minimising the risk of leakage
  • Available filled with various high quality SKF greases and oils, which are especially developed for a wide range of bearing applications
  • Dispense rate setting is a simple part of the installation process
  • Hermetic sealing prevents ingress of dirt or foreign matter
  • Allows low grease dispense rate
  • Available in two sizes: 125 ml (LAGD 125) and 60 ml (LAGD 60)
  • Can be temporarily deactivated
  • Wide range of accessories is available

A. Tool-free activation and time setting slot
Allows easy installation and accurate adjustment of lubrication flow

B. Gas cell Produces a large molecule inert gas,
which is less temperature sensitive

C. Easy-grip top-cover Facilitates easy and quick fitting

D. Special piston shape Helps ensure optimum emptying of lubricator

E. Transparent container made of polyamide
Reduces gas diffusion and increases reliability

F. High quality SKF bearing grease SKF bearing greases,
especially developed for bearing applications

G. One-piece lubricant container with an integrated base
Offers better vibration resistance

H. Removable lubricant outlet end-cap
No sharp tool is required to open the outlet

Technical Data:

  • Grease capacity:Nominal emptying time: Adjustable; 1 - 12 months
    • LAGD 125 125 ml (4.25 fl oz. US)
    • LAGD 60 60 ml (2.03 fl oz. US)
  • Ambient temperature range: -20 to 60 °C (-5 to 140 °F)
  • Maximum operating pressure: 5 bar (75 psi)
  • Drive mechanism: Gas cell producing inert gas
  • Connection thread: G 1/4
  • Maximum feed line length:
    • Grease: 300 mm (11.8 in)
    • Oil: 1 500 mm (59.1 in)
  • Intrinsically safe approval:Protection class: IP 68
    • II 1 GD EEx ia II C T6 T85 °C
    • I M 1 EEx ia I
  • Recommended storage temperature: 20 °C (70 °F)
  • Storage life of lubricator: 2 years
  • Weight:Lubricant included
    • LAGD 125: approx 200 g (7.1 oz)
    • LAGD 60: approx 130 g (4.6 oz)

System 24 Automatic Lubricator Ordering Details:

  • LAGD 125/WA2: 125 ml (4.25 fl oz. US) unit filled with LGWA 2 grease
    • Multi-purpose EP type
  • LAGD 60/WA2: 60 ml (2.03 fl oz. US) unit filled with LGWA 2 grease
    • Multi-purpose EP type
  • LAGD 125/EM2: 125 ml (4.25 fl oz. US) unit filled with LGEM 2 grease
    • High loads, slow rotations
  • LAGD 125/FP2: 125 ml (4.25 fl oz. US) unit filled with LGFP 2 grease
    • Food processing industry
  • LAGD 125/GB2: 125 ml (4.25 fl oz. US) unit filled with LGGB 2 grease
    • Biodegradable, low toxicity
  • LAGD 125/HB2: 125 ml (4.25 fl oz. US) unit filled with LGHB 2 grease
    • High temperature, loads, plain bearing
  • LAGD 125/HP2: 125 ml (4.25 fl oz. US) unit filled with LGHP 2 grease
    • High performance polyurea
  • LAGD 125/HFP15: 125 ml (4.25 fl oz. US) unit filled with HFP150 oil
    • Food processing, viscosity ISO 150
    • Includes non-return valve
  • LAGD 125/HHT26: 125 ml (4.25 fl oz. US) unit filled with HHT265 oil
    • Synthetic high temperature chain oil, viscosity ISO 265
    • Includes non-return valve
  • LAGD 125/HMT68: 125 ml (4.25 fl oz. US) unit filled with HMT68 oil
    • Mineral EP type chain oil, viscosity ISO 68
    • Includes non-return valve
  • LAGD 60/HMT68: 60 ml (2.03 fl oz. US) unit filled with HMT68 oil
    • Mineral EP type chain oil, viscosity ISO 68
    • Includes non-return valve

    • System 24 Accessory Ordering Details:
      • LAPA 45 - Angle connection 45°
      • LAPA 90 - Angle connection 90°
      • LAPB 3x4E1* - Brush 30 × 40 mm
      • LAPB 3x7E1* - Brush 30 × 70 mm
      • LAPB 3x10E1* - Brush 30 × 100 mm
      • LAPB 5-16E* - Elevator brush, 5-16 mm gap
      • LAPB D2* - Brush round Ø 20 mm
      • LAPC 50 - Clamp
      • LAPE 35 - Extension 35 mm
      • LAPE 50 - Extension 50 mm
      • LAPT 1000 - Flexible tube, 1 000 mm long, 8 × 6 mm
      • LAPF